Adds zpool split to man page
[zfs.git] / man / man8 / zpool.8
1 '\" te
2 .\" Copyright (c) 2007, Sun Microsystems, Inc. All Rights Reserved.
3 .\" Copyright 2011 Nexenta Systems, Inc.  All rights reserved.
4 .\" Copyright (c) 2012 by Delphix. All Rights Reserved.
5 .\" Copyright (c) 2012 Cyril Plisko. All Rights Reserved.
6 .\" The contents of this file are subject to the terms of the Common Development
7 .\" and Distribution License (the "License"). You may not use this file except
8 .\" in compliance with the License. You can obtain a copy of the license at
9 .\" usr/src/OPENSOLARIS.LICENSE or http://www.opensolaris.org/os/licensing.
10 .\"
11 .\" See the License for the specific language governing permissions and
12 .\" limitations under the License. When distributing Covered Code, include this
13 .\" CDDL HEADER in each file and include the License file at
14 .\" usr/src/OPENSOLARIS.LICENSE. If applicable, add the following below this
15 .\" CDDL HEADER, with the fields enclosed by brackets "[]" replaced with your
16 .\" own identifying information:
17 .\" Portions Copyright [yyyy] [name of copyright owner]
18 .TH zpool 8 "14 December 2012" "ZFS pool 28, filesystem 5" "System Administration Commands"
19 .SH NAME
20 zpool \- configures ZFS storage pools
21 .SH SYNOPSIS
22 .LP
23 .nf
24 \fBzpool\fR [\fB-?\fR]
25 .fi
26
27 .LP
28 .nf
29 \fBzpool add\fR [\fB-fn\fR] [\fB-o\fR \fIproperty=value\fR] \fIpool\fR \fIvdev\fR ...
30 .fi
31
32 .LP
33 .nf
34 \fBzpool attach\fR [\fB-f\fR] [\fB-o\fR \fIproperty=value\fR] \fIpool\fR \fIdevice\fR \fInew_device\fR
35 .fi
36
37 .LP
38 .nf
39 \fBzpool clear\fR \fIpool\fR [\fIdevice\fR]
40 .fi
41
42 .LP
43 .nf
44 \fBzpool create\fR [\fB-fnd\fR] [\fB-o\fR \fIproperty=value\fR] ... [\fB-O\fR \fIfile-system-property=value\fR]
45      ... [\fB-m\fR \fImountpoint\fR] [\fB-R\fR \fIroot\fR] \fIpool\fR \fIvdev\fR ...
46 .fi
47
48 .LP
49 .nf
50 \fBzpool destroy\fR [\fB-f\fR] \fIpool\fR
51 .fi
52
53 .LP
54 .nf
55 \fBzpool detach\fR \fIpool\fR \fIdevice\fR
56 .fi
57
58 .LP
59 .nf
60 \fBzpool export\fR [\fB-f\fR] \fIpool\fR ...
61 .fi
62
63 .LP
64 .nf
65 \fBzpool get\fR "\fIall\fR" | \fIproperty\fR[,...] \fIpool\fR ...
66 .fi
67
68 .LP
69 .nf
70 \fBzpool history\fR [\fB-il\fR] [\fIpool\fR] ...
71 .fi
72
73 .LP
74 .nf
75 \fBzpool import\fR [\fB-d\fR \fIdir\fR] [\fB-D\fR]
76 .fi
77
78 .LP
79 .nf
80 \fBzpool import\fR [\fB-o \fImntopts\fR\fR] [\fB-o\fR \fIproperty=value\fR] ... [\fB-d\fR \fIdir\fR | \fB-c\fR \fIcachefile\fR]
81      [\fB-D\fR] [\fB-f\fR] [\fB-m\fR] [\fB-N\fR] [\fB-R\fR \fIroot\fR] [\fB-F\fR [\fB-n\fR]] \fB-a\fR
82 .fi
83
84 .LP
85 .nf
86 \fBzpool import\fR [\fB-o \fImntopts\fR\fR] [\fB-o\fR \fIproperty=value\fR] ... [\fB-d\fR \fIdir\fR | \fB-c\fR \fIcachefile\fR]
87      [\fB-D\fR] [\fB-f\fR] [\fB-m\fR] [\fB-R\fR \fIroot\fR] [\fB-F\fR [\fB-n\fR]] \fIpool\fR |\fIid\fR [\fInewpool\fR]
88 .fi
89
90 .LP
91 .nf
92 \fBzpool iostat\fR [\fB-T\fR u | d ] [\fB-v\fR] [\fIpool\fR] ... [\fIinterval\fR[\fIcount\fR]]
93 .fi
94
95 .LP
96 .nf
97 \fBzpool list\fR [\fB-Hv\fR] [\fB-o\fR \fIproperty\fR[,...]] [\fIpool\fR] ...
98 .fi
99
100 .LP
101 .nf
102 \fBzpool offline\fR [\fB-t\fR] \fIpool\fR \fIdevice\fR ...
103 .fi
104
105 .LP
106 .nf
107 \fBzpool online\fR \fIpool\fR \fIdevice\fR ...
108 .fi
109
110 .LP
111 .nf
112 \fBzpool reguid\fR \fIpool\fR
113 .fi
114
115 .LP
116 .nf
117 \fBzpool reopen\fR \fIpool\fR
118 .fi
119
120 .LP
121 .nf
122 \fBzpool remove\fR \fIpool\fR \fIdevice\fR ...
123 .fi
124
125 .LP
126 .nf
127 \fBzpool replace\fR [\fB-f\fR] \fIpool\fR \fIdevice\fR [\fInew_device\fR]
128 .fi
129
130 .LP
131 .nf
132 \fBzpool scrub\fR [\fB-s\fR] \fIpool\fR ...
133 .fi
134
135 .LP
136 .nf
137 \fBzpool set\fR \fIproperty\fR=\fIvalue\fR \fIpool\fR
138 .fi
139
140 .LP
141 .nf
142 \fBzpool split\fR [\fB-n\fR] [\fB-R\fR \fIaltroot\fR] [\fB-o\fR \fIproperty=value\fR] \fIpool\fR \fInewpool\fR
143 .fi
144
145 .LP
146 .nf
147 \fBzpool status\fR [\fB-xv\fR] [\fIpool\fR] ...
148 .fi
149
150 .LP
151 .nf
152 \fBzpool upgrade\fR 
153 .fi
154
155 .LP
156 .nf
157 \fBzpool upgrade\fR \fB-v\fR
158 .fi
159
160 .LP
161 .nf
162 \fBzpool upgrade\fR [\fB-V\fR \fIversion\fR] \fB-a\fR | \fIpool\fR ...
163 .fi
164
165 .SH DESCRIPTION
166 .sp
167 .LP
168 The \fBzpool\fR command configures \fBZFS\fR storage pools. A storage pool is a collection of devices that provides physical storage and data replication for \fBZFS\fR datasets.
169 .sp
170 .LP
171 All datasets within a storage pool share the same space. See \fBzfs\fR(8) for information on managing datasets.
172 .SS "Virtual Devices (\fBvdev\fRs)"
173 .sp
174 .LP
175 A "virtual device" describes a single device or a collection of devices organized according to certain performance and fault characteristics. The following virtual devices are supported:
176 .sp
177 .ne 2
178 .mk
179 .na
180 \fB\fBdisk\fR\fR
181 .ad
182 .RS 10n
183 .rt  
184 A block device, typically located under \fB/dev\fR. \fBZFS\fR can use individual partitions, though the recommended mode of operation is to use whole disks. A disk can be specified by a full path, or it can be a shorthand name (the relative portion of the path under "/dev"). For example, "sda" is equivalent to "/dev/sda". A whole disk can be specified by omitting the partition designation. When given a whole disk, \fBZFS\fR automatically labels the disk, if necessary.
185 .RE
186
187 .sp
188 .ne 2
189 .mk
190 .na
191 \fB\fBfile\fR\fR
192 .ad
193 .RS 10n
194 .rt  
195 A regular file. The use of files as a backing store is strongly discouraged. It is designed primarily for experimental purposes, as the fault tolerance of a file is only as good as the file system of which it is a part. A file must be specified by a full path.
196 .RE
197
198 .sp
199 .ne 2
200 .mk
201 .na
202 \fB\fBmirror\fR\fR
203 .ad
204 .RS 10n
205 .rt  
206 A mirror of two or more devices. Data is replicated in an identical fashion across all components of a mirror. A mirror with \fIN\fR disks of size \fIX\fR can hold \fIX\fR bytes and can withstand (\fIN-1\fR) devices failing before data integrity is compromised.
207 .RE
208
209 .sp
210 .ne 2
211 .mk
212 .na
213 \fB\fBraidz\fR\fR
214 .ad
215 .br
216 .na
217 \fB\fBraidz1\fR\fR
218 .ad
219 .br
220 .na
221 \fB\fBraidz2\fR\fR
222 .ad
223 .br
224 .na
225 \fB\fBraidz3\fR\fR
226 .ad
227 .RS 10n
228 .rt  
229 A variation on \fBRAID-5\fR that allows for better distribution of parity and eliminates the "\fBRAID-5\fR write hole" (in which data and parity become inconsistent after a power loss). Data and parity is striped across all disks within a \fBraidz\fR group.
230 .sp
231 A \fBraidz\fR group can have single-, double- , or triple parity, meaning that the \fBraidz\fR group can sustain one, two, or three failures, respectively, without losing any data. The \fBraidz1\fR \fBvdev\fR type specifies a single-parity \fBraidz\fR group; the \fBraidz2\fR \fBvdev\fR type specifies a double-parity \fBraidz\fR group; and the \fBraidz3\fR \fBvdev\fR type specifies a triple-parity \fBraidz\fR group. The \fBraidz\fR \fBvdev\fR type is an alias for \fBraidz1\fR.
232 .sp
233 A \fBraidz\fR group with \fIN\fR disks of size \fIX\fR with \fIP\fR parity disks can hold approximately (\fIN-P\fR)*\fIX\fR bytes and can withstand \fIP\fR device(s) failing before data integrity is compromised. The minimum number of devices in a \fBraidz\fR group is one more than the number of parity disks. The recommended number is between 3 and 9 to help increase performance.
234 .RE
235
236 .sp
237 .ne 2
238 .mk
239 .na
240 \fB\fBspare\fR\fR
241 .ad
242 .RS 10n
243 .rt  
244 A special pseudo-\fBvdev\fR which keeps track of available hot spares for a pool. For more information, see the "Hot Spares" section.
245 .RE
246
247 .sp
248 .ne 2
249 .mk
250 .na
251 \fB\fBlog\fR\fR
252 .ad
253 .RS 10n
254 .rt  
255 A separate-intent log device. If more than one log device is specified, then writes are load-balanced between devices. Log devices can be mirrored. However, \fBraidz\fR \fBvdev\fR types are not supported for the intent log. For more information, see the "Intent Log" section.
256 .RE
257
258 .sp
259 .ne 2
260 .mk
261 .na
262 \fB\fBcache\fR\fR
263 .ad
264 .RS 10n
265 .rt  
266 A device used to cache storage pool data. A cache device cannot be configured as a mirror or \fBraidz\fR group. For more information, see the "Cache Devices" section.
267 .RE
268
269 .sp
270 .LP
271 Virtual devices cannot be nested, so a mirror or \fBraidz\fR virtual device can only contain files or disks. Mirrors of mirrors (or other combinations) are not allowed.
272 .sp
273 .LP
274 A pool can have any number of virtual devices at the top of the configuration (known as "root vdevs"). Data is dynamically distributed across all top-level devices to balance data among devices. As new virtual devices are added, \fBZFS\fR automatically places data on the newly available devices.
275 .sp
276 .LP
277 Virtual devices are specified one at a time on the command line, separated by whitespace. The keywords "mirror" and "raidz" are used to distinguish where a group ends and another begins. For example, the following creates two root vdevs, each a mirror of two disks:
278 .sp
279 .in +2
280 .nf
281 # \fBzpool create mypool mirror sda sdb mirror sdc sdd\fR
282 .fi
283 .in -2
284 .sp
285
286 .SS "Device Failure and Recovery"
287 .sp
288 .LP
289 \fBZFS\fR supports a rich set of mechanisms for handling device failure and data corruption. All metadata and data is checksummed, and \fBZFS\fR automatically repairs bad data from a good copy when corruption is detected.
290 .sp
291 .LP
292 In order to take advantage of these features, a pool must make use of some form of redundancy, using either mirrored or \fBraidz\fR groups. While \fBZFS\fR supports running in a non-redundant configuration, where each root vdev is simply a disk or file, this is strongly discouraged. A single case of bit corruption can render some or all of your data unavailable.
293 .sp
294 .LP
295 A pool's health status is described by one of three states: online, degraded, or faulted. An online pool has all devices operating normally. A degraded pool is one in which one or more devices have failed, but the data is still available due to a redundant configuration. A faulted pool has corrupted metadata, or one or more faulted devices, and insufficient replicas to continue functioning. 
296 .sp
297 .LP
298 The health of the top-level vdev, such as mirror or \fBraidz\fR device, is potentially impacted by the state of its associated vdevs, or component devices. A top-level vdev or component device is in one of the following states:
299 .sp
300 .ne 2
301 .mk
302 .na
303 \fB\fBDEGRADED\fR\fR
304 .ad
305 .RS 12n
306 .rt  
307 One or more top-level vdevs is in the degraded state because one or more component devices are offline. Sufficient replicas exist to continue functioning.
308 .sp
309 One or more component devices is in the degraded or faulted state, but sufficient replicas exist to continue functioning. The underlying conditions are as follows:
310 .RS +4
311 .TP
312 .ie t \(bu
313 .el o
314 The number of checksum errors exceeds acceptable levels and the device is degraded as an indication that something may be wrong. \fBZFS\fR continues to use the device as necessary.
315 .RE
316 .RS +4
317 .TP
318 .ie t \(bu
319 .el o
320 The number of I/O errors exceeds acceptable levels. The device could not be marked as faulted because there are insufficient replicas to continue functioning.
321 .RE
322 .RE
323
324 .sp
325 .ne 2
326 .mk
327 .na
328 \fB\fBFAULTED\fR\fR
329 .ad
330 .RS 12n
331 .rt  
332 One or more top-level vdevs is in the faulted state because one or more component devices are offline. Insufficient replicas exist to continue functioning. 
333 .sp
334 One or more component devices is in the faulted state, and insufficient replicas exist to continue functioning. The underlying conditions are as follows:
335 .RS +4
336 .TP
337 .ie t \(bu
338 .el o
339 The device could be opened, but the contents did not match expected values. 
340 .RE
341 .RS +4
342 .TP
343 .ie t \(bu
344 .el o
345 The number of I/O errors exceeds acceptable levels and the device is faulted to prevent further use of the device.
346 .RE
347 .RE
348
349 .sp
350 .ne 2
351 .mk
352 .na
353 \fB\fBOFFLINE\fR\fR
354 .ad
355 .RS 12n
356 .rt  
357 The device was explicitly taken offline by the "\fBzpool offline\fR" command.
358 .RE
359
360 .sp
361 .ne 2
362 .mk
363 .na
364 \fB\fBONLINE\fR\fR
365 .ad
366 .RS 12n
367 .rt  
368 The device is online and functioning.
369 .RE
370
371 .sp
372 .ne 2
373 .mk
374 .na
375 \fB\fBREMOVED\fR\fR
376 .ad
377 .RS 12n
378 .rt  
379 The device was physically removed while the system was running. Device removal detection is hardware-dependent and may not be supported on all platforms.
380 .RE
381
382 .sp
383 .ne 2
384 .mk
385 .na
386 \fB\fBUNAVAIL\fR\fR
387 .ad
388 .RS 12n
389 .rt  
390 The device could not be opened. If a pool is imported when a device was unavailable, then the device will be identified by a unique identifier instead of its path since the path was never correct in the first place.
391 .RE
392
393 .sp
394 .LP
395 If a device is removed and later re-attached to the system, \fBZFS\fR attempts to put the device online automatically. Device attach detection is hardware-dependent and might not be supported on all platforms.
396 .SS "Hot Spares"
397 .sp
398 .LP
399 \fBZFS\fR allows devices to be associated with pools as "hot spares". These devices are not actively used in the pool, but when an active device fails, it is automatically replaced by a hot spare. To create a pool with hot spares, specify a "spare" \fBvdev\fR with any number of devices. For example, 
400 .sp
401 .in +2
402 .nf
403 # zpool create pool mirror sda sdb spare sdc sdd
404 .fi
405 .in -2
406 .sp
407
408 .sp
409 .LP
410 Spares can be shared across multiple pools, and can be added with the "\fBzpool add\fR" command and removed with the "\fBzpool remove\fR" command. Once a spare replacement is initiated, a new "spare" \fBvdev\fR is created within the configuration that will remain there until the original device is replaced. At this point, the hot spare becomes available again.
411 .sp
412 .LP
413 If a pool has a shared spare that is currently being used, the pool can not be exported since other pools may use this shared spare, which may lead to potential data corruption.
414 .sp
415 .LP
416 An in-progress spare replacement can be cancelled by detaching the hot spare. If the original faulted device is detached, then the hot spare assumes its place in the configuration, and is removed from the spare list of all active pools.
417 .sp
418 .LP
419 Spares cannot replace log devices.
420 .SS "Intent Log"
421 .sp
422 .LP
423 The \fBZFS\fR Intent Log (\fBZIL\fR) satisfies \fBPOSIX\fR requirements for synchronous transactions. For instance, databases often require their transactions to be on stable storage devices when returning from a system call. \fBNFS\fR and other applications can also use \fBfsync\fR() to ensure data stability. By default, the intent log is allocated from blocks within the main pool. However, it might be possible to get better performance using separate intent log devices such as \fBNVRAM\fR or a dedicated disk. For example:
424 .sp
425 .in +2
426 .nf
427 \fB# zpool create pool sda sdb log sdc\fR
428 .fi
429 .in -2
430 .sp
431
432 .sp
433 .LP
434 Multiple log devices can also be specified, and they can be mirrored. See the EXAMPLES section for an example of mirroring multiple log devices.
435 .sp
436 .LP
437 Log devices can be added, replaced, attached, detached, and imported and exported as part of the larger pool. Mirrored log devices can be removed by specifying the top-level mirror for the log.
438 .SS "Cache Devices"
439 .sp
440 .LP
441 Devices can be added to a storage pool as "cache devices." These devices provide an additional layer of caching between main memory and disk. For read-heavy workloads, where the working set size is much larger than what can be cached in main memory, using cache devices allow much more of this working set to be served from low latency media. Using cache devices provides the greatest performance improvement for random read-workloads of mostly static content.
442 .sp
443 .LP
444 To create a pool with cache devices, specify a "cache" \fBvdev\fR with any number of devices. For example:
445 .sp
446 .in +2
447 .nf
448 \fB# zpool create pool sda sdb cache sdc sdd\fR
449 .fi
450 .in -2
451 .sp
452
453 .sp
454 .LP
455 Cache devices cannot be mirrored or part of a \fBraidz\fR configuration. If a read error is encountered on a cache device, that read \fBI/O\fR is reissued to the original storage pool device, which might be part of a mirrored or \fBraidz\fR configuration.
456 .sp
457 .LP
458 The content of the cache devices is considered volatile, as is the case with other system caches.
459 .SS "Properties"
460 .sp
461 .LP
462 Each pool has several properties associated with it. Some properties are read-only statistics while others are configurable and change the behavior of the pool. The following are read-only properties:
463 .sp
464 .ne 2
465 .mk
466 .na
467 \fB\fBavailable\fR\fR
468 .ad
469 .RS 20n
470 .rt  
471 Amount of storage available within the pool. This property can also be referred to by its shortened column name, "avail".
472 .RE
473
474 .sp
475 .ne 2
476 .mk
477 .na
478 \fB\fBcapacity\fR\fR
479 .ad
480 .RS 20n
481 .rt  
482 Percentage of pool space used. This property can also be referred to by its shortened column name, "cap".
483 .RE
484
485 .sp
486 .ne 2
487 .mk
488 .na
489 \fB\fBexpandsize\fR\fR
490 .ad
491 .RS 20n
492 Amount of uninitialized space within the pool or device that can be used to
493 increase the total capacity of the pool.  Uninitialized space consists of
494 any space on an EFI labeled vdev which has not been brought online
495 (i.e. zpool online -e).  This space occurs when a LUN is dynamically expanded.
496 .RE
497
498 .sp
499 .ne 2
500 .na
501 \fB\fBfree\fR\fR
502 .ad
503 .RS 20n
504 The amount of free space available in the pool.
505 .RE
506
507 .sp
508 .ne 2
509 .na
510 \fB\fBfreeing\fR\fR
511 .ad
512 .RS 20n
513 After a file system or snapshot is destroyed, the space it was using is
514 returned to the pool asynchronously. \fB\fBfreeing\fR\fR is the amount of
515 space remaining to be reclaimed. Over time \fB\fBfreeing\fR\fR will decrease
516 while \fB\fBfree\fR\fR increases.
517 .RE
518
519 .sp
520 .ne 2
521 .na
522 \fB\fBhealth\fR\fR
523 .ad
524 .RS 20n
525 .rt  
526 The current health of the pool. Health can be "\fBONLINE\fR", "\fBDEGRADED\fR", "\fBFAULTED\fR", " \fBOFFLINE\fR", "\fBREMOVED\fR", or "\fBUNAVAIL\fR".
527 .RE
528
529 .sp
530 .ne 2
531 .mk
532 .na
533 \fB\fBguid\fR\fR
534 .ad
535 .RS 20n
536 .rt  
537 A unique identifier for the pool.
538 .RE
539
540 .sp
541 .ne 2
542 .mk
543 .na
544 \fB\fBsize\fR\fR
545 .ad
546 .RS 20n
547 .rt  
548 Total size of the storage pool.
549 .RE
550
551 .sp
552 .ne 2
553 .na
554 \fB\fBunsupported@\fR\fIfeature_guid\fR\fR
555 .ad
556 .RS 20n
557 Information about unsupported features that are enabled on the pool. See
558 \fBzpool-features\fR(5) for details.
559 .RE
560
561 .sp
562 .ne 2
563 .mk
564 .na
565 \fB\fBused\fR\fR
566 .ad
567 .RS 20n
568 .rt  
569 Amount of storage space used within the pool.
570 .RE
571
572 .sp
573 .LP
574 The space usage properties report actual physical space available to the storage pool. The physical space can be different from the total amount of space that any contained datasets can actually use. The amount of space used in a \fBraidz\fR configuration depends on the characteristics of the data being written. In addition, \fBZFS\fR reserves some space for internal accounting that the \fBzfs\fR(8) command takes into account, but the \fBzpool\fR command does not. For non-full pools of a reasonable size, these effects should be invisible. For small pools, or pools that are close to being completely full, these discrepancies may become more noticeable.
575
576 .sp
577 .LP
578 The following property can be set at creation time:
579 .sp
580 .ne 2
581 .mk
582 .na
583 \fB\fBashift\fR\fR
584 .ad
585 .sp .6
586 .RS 4n
587 Pool sector size exponent, to the power of 2 (internally referred to as "ashift"). I/O operations will be aligned to the specified size boundaries. Additionally, the minimum (disk) write size will be set to the specified size, so this represents a space vs. performance trade-off. The typical case for setting this property is when performance is important and the underlying disks use 4KiB sectors but report 512B sectors to the OS (for compatibility reasons); in that case, set \fBashift=12\fR (which is 1<<12 = 4096).
588 .LP
589 For optimal performance, the pool sector size should be greater than or equal to the sector size of the underlying disks. Since the property cannot be changed after pool creation, if in a given pool, you \fIever\fR want to use drives that \fIreport\fR 4KiB sectors, you must set \fBashift=12\fR at pool creation time.
590 .RE
591
592 .sp
593 .LP
594 The following property can be set at creation time and import time:
595 .sp
596 .ne 2
597 .mk
598 .na
599 \fB\fBaltroot\fR\fR
600 .ad
601 .sp .6
602 .RS 4n
603 Alternate root directory. If set, this directory is prepended to any mount points within the pool. This can be used when examining an unknown pool where the mount points cannot be trusted, or in an alternate boot environment, where the typical paths are not valid. \fBaltroot\fR is not a persistent property. It is valid only while the system is up. Setting \fBaltroot\fR defaults to using \fBcachefile\fR=none, though this may be overridden using an explicit setting.
604 .RE
605
606 .sp
607 .LP
608 The following properties can be set at creation time and import time, and later changed with the \fBzpool set\fR command:
609 .sp
610 .ne 2
611 .mk
612 .na
613 \fB\fBautoexpand\fR=\fBon\fR | \fBoff\fR\fR
614 .ad
615 .sp .6
616 .RS 4n
617 Controls automatic pool expansion when the underlying LUN is grown. If set to \fBon\fR, the pool will be resized according to the size of the expanded device. If the device is part of a mirror or \fBraidz\fR then all devices within that mirror/\fBraidz\fR group must be expanded before the new space is made available to the pool. The default behavior is \fBoff\fR. This property can also be referred to by its shortened column name, \fBexpand\fR.
618 .RE
619
620 .sp
621 .ne 2
622 .mk
623 .na
624 \fB\fBautoreplace\fR=\fBon\fR | \fBoff\fR\fR
625 .ad
626 .sp .6
627 .RS 4n
628 Controls automatic device replacement. If set to "\fBoff\fR", device replacement must be initiated by the administrator by using the "\fBzpool replace\fR" command. If set to "\fBon\fR", any new device, found in the same physical location as a device that previously belonged to the pool, is automatically formatted and replaced. The default behavior is "\fBoff\fR". This property can also be referred to by its shortened column name, "replace".
629 .RE
630
631 .sp
632 .ne 2
633 .mk
634 .na
635 \fB\fBbootfs\fR=\fIpool\fR/\fIdataset\fR\fR
636 .ad
637 .sp .6
638 .RS 4n
639 Identifies the default bootable dataset for the root pool. This property is expected to be set mainly by the installation and upgrade programs.
640 .RE
641
642 .sp
643 .ne 2
644 .mk
645 .na
646 \fB\fBcachefile\fR=\fIpath\fR | \fBnone\fR\fR
647 .ad
648 .sp .6
649 .RS 4n
650 Controls the location of where the pool configuration is cached. Discovering all pools on system startup requires a cached copy of the configuration data that is stored on the root file system. All pools in this cache are automatically imported when the system boots. Some environments, such as install and clustering, need to cache this information in a different location so that pools are not automatically imported. Setting this property caches the pool configuration in a different location that can later be imported with "\fBzpool import -c\fR". Setting it to the special value "\fBnone\fR" creates a temporary pool that is never cached, and the special value \fB\&''\fR (empty string) uses the default location. 
651 .sp
652 Multiple pools can share the same cache file. Because the kernel destroys and recreates this file when pools are added and removed, care should be taken when attempting to access this file. When the last pool using a \fBcachefile\fR is exported or destroyed, the file is removed.
653 .RE
654
655 .sp
656 .ne 2
657 .mk
658 .na
659 \fB\fBcomment\fR=\fB\fItext\fR\fR
660 .ad
661 .sp .6
662 .RS 4n
663 A text string consisting of printable ASCII characters that will be stored such that it is available even if the pool becomes faulted.  An administrator can provide additional information about a pool using this property.
664 .RE
665
666 .sp
667 .ne 2
668 .mk
669 .na
670 \fB\fBdelegation\fR=\fBon\fR | \fBoff\fR\fR
671 .ad
672 .sp .6
673 .RS 4n
674 Controls whether a non-privileged user is granted access based on the dataset permissions defined on the dataset. See \fBzfs\fR(8) for more information on \fBZFS\fR delegated administration.
675 .RE
676
677 .sp
678 .ne 2
679 .mk
680 .na
681 \fB\fBfailmode\fR=\fBwait\fR | \fBcontinue\fR | \fBpanic\fR\fR
682 .ad
683 .sp .6
684 .RS 4n
685 Controls the system behavior in the event of catastrophic pool failure. This condition is typically a result of a loss of connectivity to the underlying storage device(s) or a failure of all devices within the pool. The behavior of such an event is determined as follows:
686 .sp
687 .ne 2
688 .mk
689 .na
690 \fB\fBwait\fR\fR
691 .ad
692 .RS 12n
693 .rt  
694 Blocks all \fBI/O\fR access until the device connectivity is recovered and the errors are cleared. This is the default behavior.
695 .RE
696
697 .sp
698 .ne 2
699 .mk
700 .na
701 \fB\fBcontinue\fR\fR
702 .ad
703 .RS 12n
704 .rt  
705 Returns \fBEIO\fR to any new write \fBI/O\fR requests but allows reads to any of the remaining healthy devices. Any write requests that have yet to be committed to disk would be blocked.
706 .RE
707
708 .sp
709 .ne 2
710 .mk
711 .na
712 \fB\fBpanic\fR\fR
713 .ad
714 .RS 12n
715 .rt  
716 Prints out a message to the console and generates a system crash dump.
717 .RE
718
719 .RE
720
721 .sp
722 .ne 2
723 .na
724 \fB\fBfeature@\fR\fIfeature_name\fR=\fBenabled\fR\fR
725 .ad
726 .RS 4n
727 The value of this property is the current state of \fIfeature_name\fR. The
728 only valid value when setting this property is \fBenabled\fR which moves
729 \fIfeature_name\fR to the enabled state. See \fBzpool-features\fR(5) for
730 details on feature states.
731 .RE
732
733 .sp
734 .ne 2
735 .mk
736 .na
737 \fB\fBlistsnaps\fR=on | off\fR
738 .ad
739 .sp .6
740 .RS 4n
741 Controls whether information about snapshots associated with this pool is output when "\fBzfs list\fR" is run without the \fB-t\fR option. The default value is "off".
742 .RE
743
744 .sp
745 .ne 2
746 .mk
747 .na
748 \fB\fBversion\fR=\fIversion\fR\fR
749 .ad
750 .sp .6
751 .RS 4n
752 The current on-disk version of the pool. This can be increased, but never decreased. The preferred method of updating pools is with the "\fBzpool upgrade\fR" command, though this property can be used when a specific version is needed for backwards compatibility. Once feature flags are enabled on a pool this property will no longer have a value.
753 .RE
754
755 .SS "Subcommands"
756 .sp
757 .LP
758 All subcommands that modify state are logged persistently to the pool in their original form.
759 .sp
760 .LP
761 The \fBzpool\fR command provides subcommands to create and destroy storage pools, add capacity to storage pools, and provide information about the storage pools. The following subcommands are supported:
762 .sp
763 .ne 2
764 .mk
765 .na
766 \fB\fBzpool\fR \fB-?\fR\fR
767 .ad
768 .sp .6
769 .RS 4n
770 Displays a help message.
771 .RE
772
773 .sp
774 .ne 2
775 .mk
776 .na
777 \fB\fBzpool add\fR [\fB-fn\fR] [\fB-o\fR \fIproperty=value\fR] \fIpool\fR \fIvdev\fR ...\fR
778 .ad
779 .sp .6
780 .RS 4n
781 Adds the specified virtual devices to the given pool. The \fIvdev\fR specification is described in the "Virtual Devices" section. The behavior of the \fB-f\fR option, and the device checks performed are described in the "zpool create" subcommand.
782 .sp
783 .ne 2
784 .mk
785 .na
786 \fB\fB-f\fR\fR
787 .ad
788 .RS 6n
789 .rt  
790 Forces use of \fBvdev\fRs, even if they appear in use or specify a conflicting replication level. Not all devices can be overridden in this manner.
791 .RE
792
793 .sp
794 .ne 2
795 .mk
796 .na
797 \fB\fB-n\fR\fR
798 .ad
799 .RS 6n
800 .rt  
801 Displays the configuration that would be used without actually adding the \fBvdev\fRs. The actual pool creation can still fail due to insufficient privileges or device sharing.
802 .RE
803
804 .sp
805 .ne 2
806 .mk
807 .na
808 \fB\fB-o\fR \fIproperty=value\fR
809 .ad
810 .sp .6
811 .RS 4n
812 Sets the given pool properties. See the "Properties" section for a list of valid properties that can be set. The only property supported at the moment is "ashift".
813 .RE
814
815 Do not add a disk that is currently configured as a quorum device to a zpool. After a disk is in the pool, that disk can then be configured as a quorum device.
816 .RE
817
818 .sp
819 .ne 2
820 .mk
821 .na
822 \fB\fBzpool attach\fR [\fB-f\fR] [\fB-o\fR \fIproperty=value\fR] \fIpool\fR \fIdevice\fR \fInew_device\fR\fR
823 .ad
824 .sp .6
825 .RS 4n
826 Attaches \fInew_device\fR to an existing \fBzpool\fR device. The existing device cannot be part of a \fBraidz\fR configuration. If \fIdevice\fR is not currently part of a mirrored configuration, \fIdevice\fR automatically transforms into a two-way mirror of \fIdevice\fR and \fInew_device\fR. If \fIdevice\fR is part of a two-way mirror, attaching \fInew_device\fR creates a three-way mirror, and so on. In either case, \fInew_device\fR begins to resilver immediately.
827 .sp
828 .ne 2
829 .mk
830 .na
831 \fB\fB-f\fR\fR
832 .ad
833 .RS 6n
834 .rt  
835 Forces use of \fInew_device\fR, even if its appears to be in use. Not all devices can be overridden in this manner.
836 .RE
837
838 .sp
839 .ne 2
840 .mk
841 .na
842 \fB\fB-o\fR \fIproperty=value\fR
843 .ad
844 .sp .6
845 .RS 4n
846 Sets the given pool properties. See the "Properties" section for a list of valid properties that can be set. The only property supported at the moment is "ashift".
847 .RE
848
849 .RE
850
851 .sp
852 .ne 2
853 .mk
854 .na
855 \fB\fBzpool clear\fR \fIpool\fR [\fIdevice\fR] ...\fR
856 .ad
857 .sp .6
858 .RS 4n
859 Clears device errors in a pool. If no arguments are specified, all device errors within the pool are cleared. If one or more devices is specified, only those errors associated with the specified device or devices are cleared.
860 .RE
861
862 .sp
863 .ne 2
864 .mk
865 .na
866 \fB\fBzpool create\fR [\fB-fnd\fR] [\fB-o\fR \fIproperty=value\fR] ... [\fB-O\fR \fIfile-system-property=value\fR] ... [\fB-m\fR \fImountpoint\fR] [\fB-R\fR \fIroot\fR] \fIpool\fR \fIvdev\fR ...\fR
867 .ad
868 .sp .6
869 .RS 4n
870 Creates a new storage pool containing the virtual devices specified on the command line. The pool name must begin with a letter, and can only contain alphanumeric characters as well as underscore ("_"), dash ("-"), period ("."), colon (":"), and space (" "). The pool names "mirror", "raidz", "spare" and "log" are reserved, as are names beginning with the pattern "c[0-9]". The \fBvdev\fR specification is described in the "Virtual Devices" section.
871 .sp
872 The command verifies that each device specified is accessible and not currently in use by another subsystem. There are some uses, such as being currently mounted, or specified as the dedicated dump device, that prevents a device from ever being used by \fBZFS\fR. Other uses, such as having a preexisting \fBUFS\fR file system, can be overridden with the \fB-f\fR option.
873 .sp
874 The command also checks that the replication strategy for the pool is consistent. An attempt to combine redundant and non-redundant storage in a single pool, or to mix disks and files, results in an error unless \fB-f\fR is specified. The use of differently sized devices within a single \fBraidz\fR or mirror group is also flagged as an error unless \fB-f\fR is specified.
875 .sp
876 Unless the \fB-R\fR option is specified, the default mount point is "/\fIpool\fR". The mount point must not exist or must be empty, or else the root dataset cannot be mounted. This can be overridden with the \fB-m\fR option.
877 .sp
878 By default all supported features are enabled on the new pool unless the \fB-d\fR option is specified.
879 .sp
880 .ne 2
881 .mk
882 .na
883 \fB\fB-f\fR\fR
884 .ad
885 .sp .6
886 .RS 4n
887 Forces use of \fBvdev\fRs, even if they appear in use or specify a conflicting replication level. Not all devices can be overridden in this manner.
888 .RE
889
890 .sp
891 .ne 2
892 .mk
893 .na
894 \fB\fB-n\fR\fR
895 .ad
896 .sp .6
897 .RS 4n
898 Displays the configuration that would be used without actually creating the pool. The actual pool creation can still fail due to insufficient privileges or device sharing.
899 .RE
900
901 .sp
902 .ne 2
903 .mk
904 .na
905 \fB\fB-d\fR\fR
906 .ad
907 .sp .6
908 .RS 4n
909 Do not enable any features on the new pool. Individual features can be enabled by setting their corresponding properties to \fBenabled\fR with the \fB-o\fR option. See \fBzpool-features\fR(5) for details about feature properties.
910 .RE
911
912 .sp
913 .ne 2
914 .na
915 \fB\fB-o\fR \fIproperty=value\fR [\fB-o\fR \fIproperty=value\fR] ...\fR
916 .ad
917 .sp .6
918 .RS 4n
919 Sets the given pool properties. See the "Properties" section for a list of valid properties that can be set.
920 .RE
921
922 .sp
923 .ne 2
924 .mk
925 .na
926 \fB\fB-O\fR \fIfile-system-property=value\fR\fR
927 .ad
928 .br
929 .na
930 \fB[\fB-O\fR \fIfile-system-property=value\fR] ...\fR
931 .ad
932 .sp .6
933 .RS 4n
934 Sets the given file system properties in the root file system of the pool. See the "Properties" section of \fBzfs\fR(8) for a list of valid properties that can be set.
935 .RE
936
937 .sp
938 .ne 2
939 .mk
940 .na
941 \fB\fB-R\fR \fIroot\fR\fR
942 .ad
943 .sp .6
944 .RS 4n
945 Equivalent to "-o cachefile=none,altroot=\fIroot\fR"
946 .RE
947
948 .sp
949 .ne 2
950 .mk
951 .na
952 \fB\fB-m\fR \fImountpoint\fR\fR
953 .ad
954 .sp .6
955 .RS 4n
956 Sets the mount point for the root dataset. The default mount point is "/\fIpool\fR" or "\fBaltroot\fR/\fIpool\fR" if \fBaltroot\fR is specified. The mount point must be an absolute path, "\fBlegacy\fR", or "\fBnone\fR". For more information on dataset mount points, see \fBzfs\fR(8).
957 .RE
958
959 .RE
960
961 .sp
962 .ne 2
963 .mk
964 .na
965 \fB\fBzpool destroy\fR [\fB-f\fR] \fIpool\fR\fR
966 .ad
967 .sp .6
968 .RS 4n
969 Destroys the given pool, freeing up any devices for other use. This command tries to unmount any active datasets before destroying the pool.
970 .sp
971 .ne 2
972 .mk
973 .na
974 \fB\fB-f\fR\fR
975 .ad
976 .RS 6n
977 .rt  
978 Forces any active datasets contained within the pool to be unmounted.
979 .RE
980
981 .RE
982
983 .sp
984 .ne 2
985 .mk
986 .na
987 \fB\fBzpool detach\fR \fIpool\fR \fIdevice\fR\fR
988 .ad
989 .sp .6
990 .RS 4n
991 Detaches \fIdevice\fR from a mirror. The operation is refused if there are no other valid replicas of the data.
992 .RE
993
994 .sp
995 .ne 2
996 .mk
997 .na
998 \fB\fBzpool export\fR [\fB-f\fR] \fIpool\fR ...\fR
999 .ad
1000 .sp .6
1001 .RS 4n
1002 Exports the given pools from the system. All devices are marked as exported, but are still considered in use by other subsystems. The devices can be moved between systems (even those of different endianness) and imported as long as a sufficient number of devices are present.
1003 .sp
1004 Before exporting the pool, all datasets within the pool are unmounted. A pool can not be exported if it has a shared spare that is currently being used.
1005 .sp
1006 For pools to be portable, you must give the \fBzpool\fR command whole disks, not just partitions, so that \fBZFS\fR can label the disks with portable \fBEFI\fR labels. Otherwise, disk drivers on platforms of different endianness will not recognize the disks.
1007 .sp
1008 .ne 2
1009 .mk
1010 .na
1011 \fB\fB-f\fR\fR
1012 .ad
1013 .RS 6n
1014 .rt  
1015 Forcefully unmount all datasets, using the "\fBunmount -f\fR" command.
1016 .sp
1017 This command will forcefully export the pool even if it has a shared spare that is currently being used. This may lead to potential data corruption.
1018 .RE
1019
1020 .RE
1021
1022 .sp
1023 .ne 2
1024 .mk
1025 .na
1026 \fB\fBzpool get\fR "\fIall\fR" | \fIproperty\fR[,...] \fIpool\fR ...\fR
1027 .ad
1028 .sp .6
1029 .RS 4n
1030 Retrieves the given list of properties (or all properties if "\fBall\fR" is used) for the specified storage pool(s). These properties are displayed with the following fields:
1031 .sp
1032 .in +2
1033 .nf
1034        name          Name of storage pool
1035         property      Property name
1036         value         Property value
1037         source        Property source, either 'default' or 'local'.
1038 .fi
1039 .in -2
1040 .sp
1041
1042 See the "Properties" section for more information on the available pool properties.
1043 .RE
1044
1045 .sp
1046 .ne 2
1047 .mk
1048 .na
1049 \fB\fBzpool history\fR [\fB-il\fR] [\fIpool\fR] ...\fR
1050 .ad
1051 .sp .6
1052 .RS 4n
1053 Displays the command history of the specified pools or all pools if no pool is specified.
1054 .sp
1055 .ne 2
1056 .mk
1057 .na
1058 \fB\fB-i\fR\fR
1059 .ad
1060 .RS 6n
1061 .rt  
1062 Displays internally logged \fBZFS\fR events in addition to user initiated events.
1063 .RE
1064
1065 .sp
1066 .ne 2
1067 .mk
1068 .na
1069 \fB\fB-l\fR\fR
1070 .ad
1071 .RS 6n
1072 .rt  
1073 Displays log records in long format, which in addition to standard format includes, the user name, the hostname, and the zone in which the operation was performed.
1074 .RE
1075
1076 .RE
1077
1078 .sp
1079 .ne 2
1080 .mk
1081 .na
1082 \fB\fBzpool import\fR [\fB-d\fR \fIdir\fR | \fB-c\fR \fIcachefile\fR] [\fB-D\fR]\fR
1083 .ad
1084 .sp .6
1085 .RS 4n
1086 Lists pools available to import. If the \fB-d\fR option is not specified, this command searches for devices in "/dev". The \fB-d\fR option can be specified multiple times, and all directories are searched. If the device appears to be part of an exported pool, this command displays a summary of the pool with the name of the pool, a numeric identifier, as well as the \fIvdev\fR layout and current health of the device for each device or file. Destroyed pools, pools that were previously destroyed with the "\fBzpool destroy\fR" command, are not listed unless the \fB-D\fR option is specified. 
1087 .sp
1088 The numeric identifier is unique, and can be used instead of the pool name when multiple exported pools of the same name are available.
1089 .sp
1090 .ne 2
1091 .mk
1092 .na
1093 \fB\fB-c\fR \fIcachefile\fR\fR
1094 .ad
1095 .RS 16n
1096 .rt  
1097 Reads configuration from the given \fBcachefile\fR that was created with the "\fBcachefile\fR" pool property. This \fBcachefile\fR is used instead of searching for devices.
1098 .RE
1099
1100 .sp
1101 .ne 2
1102 .mk
1103 .na
1104 \fB\fB-d\fR \fIdir\fR\fR
1105 .ad
1106 .RS 16n
1107 .rt  
1108 Searches for devices or files in \fIdir\fR. The \fB-d\fR option can be specified multiple times. 
1109 .RE
1110
1111 .sp
1112 .ne 2
1113 .mk
1114 .na
1115 \fB\fB-D\fR\fR
1116 .ad
1117 .RS 16n
1118 .rt  
1119 Lists destroyed pools only.
1120 .RE
1121
1122 .RE
1123
1124 .sp
1125 .ne 2
1126 .mk
1127 .na
1128 \fB\fBzpool import\fR [\fB-o\fR \fImntopts\fR] [ \fB-o\fR \fIproperty\fR=\fIvalue\fR] ... [\fB-d\fR \fIdir\fR | \fB-c\fR \fIcachefile\fR] [\fB-D\fR] [\fB-f\fR] [\fB-m\fR] [\fB-N\fR] [\fB-R\fR \fIroot\fR] [\fB-F\fR [\fB-n\fR]] \fB-a\fR\fR
1129 .ad
1130 .sp .6
1131 .RS 4n
1132 Imports all pools found in the search directories. Identical to the previous command, except that all pools with a sufficient number of devices available are imported. Destroyed pools, pools that were previously destroyed with the "\fBzpool destroy\fR" command, will not be imported unless the \fB-D\fR option is specified.
1133 .sp
1134 .ne 2
1135 .mk
1136 .na
1137 \fB\fB-o\fR \fImntopts\fR\fR
1138 .ad
1139 .RS 21n
1140 .rt  
1141 Comma-separated list of mount options to use when mounting datasets within the pool. See \fBzfs\fR(8) for a description of dataset properties and mount options.
1142 .RE
1143
1144 .sp
1145 .ne 2
1146 .mk
1147 .na
1148 \fB\fB-o\fR \fIproperty=value\fR\fR
1149 .ad
1150 .RS 21n
1151 .rt  
1152 Sets the specified property on the imported pool. See the "Properties" section for more information on the available pool properties.
1153 .RE
1154
1155 .sp
1156 .ne 2
1157 .mk
1158 .na
1159 \fB\fB-c\fR \fIcachefile\fR\fR
1160 .ad
1161 .RS 21n
1162 .rt  
1163 Reads configuration from the given \fBcachefile\fR that was created with the "\fBcachefile\fR" pool property. This \fBcachefile\fR is used instead of searching for devices.
1164 .RE
1165
1166 .sp
1167 .ne 2
1168 .mk
1169 .na
1170 \fB\fB-d\fR \fIdir\fR\fR
1171 .ad
1172 .RS 21n
1173 .rt  
1174 Searches for devices or files in \fIdir\fR. The \fB-d\fR option can be specified multiple times. This option is incompatible with the \fB-c\fR option.
1175 .RE
1176
1177 .sp
1178 .ne 2
1179 .mk
1180 .na
1181 \fB\fB-D\fR\fR
1182 .ad
1183 .RS 21n
1184 .rt  
1185 Imports destroyed pools only. The \fB-f\fR option is also required.
1186 .RE
1187
1188 .sp
1189 .ne 2
1190 .mk
1191 .na
1192 \fB\fB-f\fR\fR
1193 .ad
1194 .RS 21n
1195 .rt  
1196 Forces import, even if the pool appears to be potentially active.
1197 .RE
1198
1199 .sp
1200 .ne 2
1201 .mk
1202 .na
1203 \fB\fB-F\fR\fR
1204 .ad
1205 .RS 21n
1206 Recovery mode for a non-importable pool. Attempt to return the pool to an importable state by discarding the last few transactions. Not all damaged pools can be recovered by using this option. If successful, the data from the discarded transactions is irretrievably lost. This option is ignored if the pool is importable or already imported.
1207 .RE
1208
1209 .sp
1210 .ne 2
1211 .mk
1212 .na
1213 \fB\fB-a\fR\fR
1214 .ad
1215 .RS 21n
1216 .rt  
1217 Searches for and imports all pools found. 
1218 .RE
1219
1220 .sp
1221 .ne 2
1222 .mk
1223 .na
1224 \fB\fB-m\fR\fR
1225 .ad
1226 .RS 21n
1227 Allows a pool to import when there is a missing log device.
1228 .RE
1229
1230 .sp
1231 .ne 2
1232 .mk
1233 .na
1234 \fB\fB-R\fR \fIroot\fR\fR
1235 .ad
1236 .RS 21n
1237 .rt  
1238 Sets the "\fBcachefile\fR" property to "\fBnone\fR" and the "\fIaltroot\fR" property to "\fIroot\fR".
1239 .RE
1240
1241 .sp
1242 .ne 2
1243 .mk
1244 .na
1245 \fB\fB-N\fR\fR
1246 .ad
1247 .RS 21n
1248 Import the pool without mounting any file systems.
1249 .RE
1250
1251 .sp
1252 .ne 2
1253 .mk
1254 .na
1255 \fB\fB-n\fR\fR
1256 .ad
1257 .RS 21n
1258 Used with the \fB-F\fR recovery option. Determines whether a non-importable pool can be made importable again, but does not actually perform the pool recovery. For more details about pool recovery mode, see the \fB-F\fR option, above.
1259 .RE
1260
1261 .RE
1262
1263 .sp
1264 .ne 2
1265 .mk
1266 .na
1267 \fB\fBzpool import\fR [\fB-o\fR \fImntopts\fR] [ \fB-o\fR \fIproperty\fR=\fIvalue\fR] ... [\fB-d\fR \fIdir\fR | \fB-c\fR \fIcachefile\fR] [\fB-D\fR] [\fB-f\fR] [\fB-m\fR] [\fB-R\fR \fIroot\fR] [\fB-F\fR [\fB-n\fR]] \fIpool\fR | \fIid\fR [\fInewpool\fR]\fR
1268 .ad
1269 .sp .6
1270 .RS 4n
1271 Imports a specific pool. A pool can be identified by its name or the numeric identifier. If \fInewpool\fR is specified, the pool is imported using the name \fInewpool\fR. Otherwise, it is imported with the same name as its exported name.
1272 .sp
1273 If a device is removed from a system without running "\fBzpool export\fR" first, the device appears as potentially active. It cannot be determined if this was a failed export, or whether the device is really in use from another host. To import a pool in this state, the \fB-f\fR option is required.
1274 .sp
1275 .ne 2
1276 .mk
1277 .na
1278 \fB\fB-o\fR \fImntopts\fR\fR
1279 .ad
1280 .sp .6
1281 .RS 4n
1282 Comma-separated list of mount options to use when mounting datasets within the pool. See \fBzfs\fR(8) for a description of dataset properties and mount options.
1283 .RE
1284
1285 .sp
1286 .ne 2
1287 .mk
1288 .na
1289 \fB\fB-o\fR \fIproperty=value\fR\fR
1290 .ad
1291 .sp .6
1292 .RS 4n
1293 Sets the specified property on the imported pool. See the "Properties" section for more information on the available pool properties.
1294 .RE
1295
1296 .sp
1297 .ne 2
1298 .mk
1299 .na
1300 \fB\fB-c\fR \fIcachefile\fR\fR
1301 .ad
1302 .sp .6
1303 .RS 4n
1304 Reads configuration from the given \fBcachefile\fR that was created with the "\fBcachefile\fR" pool property. This \fBcachefile\fR is used instead of searching for devices.
1305 .RE
1306
1307 .sp
1308 .ne 2
1309 .mk
1310 .na
1311 \fB\fB-d\fR \fIdir\fR\fR
1312 .ad
1313 .sp .6
1314 .RS 4n
1315 Searches for devices or files in \fIdir\fR. The \fB-d\fR option can be specified multiple times. This option is incompatible with the \fB-c\fR option.
1316 .RE
1317
1318 .sp
1319 .ne 2
1320 .mk
1321 .na
1322 \fB\fB-D\fR\fR
1323 .ad
1324 .sp .6
1325 .RS 4n
1326 Imports destroyed pool. The \fB-f\fR option is also required.
1327 .RE
1328
1329 .sp
1330 .ne 2
1331 .mk
1332 .na
1333 \fB\fB-f\fR\fR
1334 .ad
1335 .sp .6
1336 .RS 4n
1337 Forces import, even if the pool appears to be potentially active.
1338 .RE
1339
1340 .sp
1341 .ne 2
1342 .mk
1343 .na
1344 \fB\fB-F\fR\fR
1345 .ad
1346 .sp .6
1347 .RS 4n
1348 Recovery mode for a non-importable pool. Attempt to return the pool to an importable state by discarding the last few transactions. Not all damaged pools can be recovered by using this option. If successful, the data from the discarded transactions is irretrievably lost. This option is ignored if the pool is importable or already imported.
1349 .RE
1350
1351 .sp
1352 .ne 2
1353 .mk
1354 .na
1355 \fB\fB-R\fR \fIroot\fR\fR
1356 .ad
1357 .sp .6
1358 .RS 4n
1359 Sets the "\fBcachefile\fR" property to "\fBnone\fR" and the "\fIaltroot\fR" property to "\fIroot\fR".
1360 .RE
1361
1362 .sp
1363 .ne 2
1364 .mk
1365 .na
1366 \fB\fB-n\fR\fR
1367 .ad
1368 .sp .6
1369 .RS 4n
1370 Used with the \fB-F\fR recovery option. Determines whether a non-importable pool can be made importable again, but does not actually perform the pool recovery. For more details about pool recovery mode, see the \fB-F\fR option, above.
1371 .RE
1372
1373 .sp
1374 .ne 2
1375 .mk
1376 .na
1377 \fB\fB-m\fR\fR
1378 .ad
1379 .sp .6
1380 .RS 4n
1381 Allows a pool to import when there is a missing log device.
1382 .RE
1383
1384 .RE
1385
1386 .sp
1387 .ne 2
1388 .mk
1389 .na
1390 \fB\fBzpool iostat\fR [\fB-T\fR \fBu\fR | \fBd\fR] [\fB-v\fR] [\fIpool\fR] ... [\fIinterval\fR[\fIcount\fR]]\fR
1391 .ad
1392 .sp .6
1393 .RS 4n
1394 Displays \fBI/O\fR statistics for the given pools. When given an interval, the statistics are printed every \fIinterval\fR seconds until \fBCtrl-C\fR is pressed. If no \fIpools\fR are specified, statistics for every pool in the system is shown. If \fIcount\fR is specified, the command exits after \fIcount\fR reports are printed.
1395 .sp
1396 .ne 2
1397 .mk
1398 .na
1399 \fB\fB-T\fR \fBu\fR | \fBd\fR\fR
1400 .ad
1401 .RS 12n
1402 .rt  
1403 Display a time stamp.
1404 .sp
1405 Specify \fBu\fR for a printed representation of the internal representation of time. See \fBtime\fR(2). Specify \fBd\fR for standard date format. See \fBdate\fR(1).
1406 .RE
1407
1408 .sp
1409 .ne 2
1410 .mk
1411 .na
1412 \fB\fB-v\fR\fR
1413 .ad
1414 .RS 12n
1415 .rt  
1416 Verbose statistics. Reports usage statistics for individual \fIvdevs\fR within the pool, in addition to the pool-wide statistics.
1417 .RE
1418
1419 .RE
1420
1421 .sp
1422 .ne 2
1423 .mk
1424 .na
1425 \fB\fBzpool list\fR [\fB-Hv\fR] [\fB-o\fR \fIprops\fR[,...]] [\fIpool\fR] ...\fR
1426 .ad
1427 .sp .6
1428 .RS 4n
1429 Lists the given pools along with a health status and space usage. When given no arguments, all pools in the system are listed.
1430 .sp
1431 .ne 2
1432 .mk
1433 .na
1434 \fB\fB-H\fR\fR
1435 .ad
1436 .RS 12n
1437 .rt  
1438 Scripted mode. Do not display headers, and separate fields by a single tab instead of arbitrary space.
1439 .RE
1440
1441 .sp
1442 .ne 2
1443 .mk
1444 .na
1445 \fB\fB-o\fR \fIprops\fR\fR
1446 .ad
1447 .RS 12n
1448 .rt  
1449 Comma-separated list of properties to display. See the "Properties" section for a list of valid properties. The default list is "name, size, used, available, expandsize, capacity, dedupratio, health, altroot"
1450 .RE
1451
1452 .sp
1453 .ne 2
1454 .mk
1455 .na
1456 \fB\fB-v\fR\fR
1457 .ad
1458 .RS 12n
1459 .rt
1460 Verbose statistics. Reports usage statistics for individual \fIvdevs\fR within the pool, in addition to the pool-wise statistics.
1461 .RE
1462
1463 .RE
1464
1465 .sp
1466 .ne 2
1467 .mk
1468 .na
1469 \fB\fBzpool offline\fR [\fB-t\fR] \fIpool\fR \fIdevice\fR ...\fR
1470 .ad
1471 .sp .6
1472 .RS 4n
1473 Takes the specified physical device offline. While the \fIdevice\fR is offline, no attempt is made to read or write to the device.
1474 .sp
1475 This command is not applicable to spares or cache devices.
1476 .sp
1477 .ne 2
1478 .mk
1479 .na
1480 \fB\fB-t\fR\fR
1481 .ad
1482 .RS 6n
1483 .rt  
1484 Temporary. Upon reboot, the specified physical device reverts to its previous state.
1485 .RE
1486
1487 .RE
1488
1489 .sp
1490 .ne 2
1491 .mk
1492 .na
1493 \fB\fBzpool online\fR [\fB-e\fR] \fIpool\fR \fIdevice\fR...\fR
1494 .ad
1495 .sp .6
1496 .RS 4n
1497 Brings the specified physical device online.
1498 .sp
1499 This command is not applicable to spares or cache devices.
1500 .sp
1501 .ne 2
1502 .mk
1503 .na
1504 \fB\fB-e\fR\fR
1505 .ad
1506 .RS 6n
1507 .rt  
1508 Expand the device to use all available space. If the device is part of a mirror or \fBraidz\fR then all devices must be expanded before the new space will become available to the pool.
1509 .RE
1510
1511 .RE
1512
1513 .sp
1514 .ne 2
1515 .mk
1516 .na
1517 \fB\fBzpool reguid\fR \fIpool\fR
1518 .ad
1519 .sp .6
1520 .RS 4n
1521 Generates a new unique identifier for the pool. You must ensure that all
1522 devices in this pool are online and healthy before performing this action.
1523 .RE
1524
1525 .sp
1526 .ne 2
1527 .na
1528 \fB\fBzpool reopen\fR \fIpool\fR
1529 .ad
1530 .sp .6
1531 .RS 4n
1532 Reopen all the vdevs associated with the pool.
1533 .RE
1534
1535 .sp
1536 .ne 2
1537 .na
1538 \fB\fBzpool remove\fR \fIpool\fR \fIdevice\fR ...\fR
1539 .ad
1540 .sp .6
1541 .RS 4n
1542 Removes the specified device from the pool. This command currently only supports removing hot spares, cache, and log devices. A mirrored log device can be removed by specifying the top-level mirror for the log. Non-log devices that are part of a mirrored configuration can be removed using the \fBzpool detach\fR command. Non-redundant and \fBraidz\fR devices cannot be removed from a pool.
1543 .RE
1544
1545 .sp
1546 .ne 2
1547 .mk
1548 .na
1549 \fB\fBzpool replace\fR [\fB-f\fR] \fIpool\fR \fIold_device\fR [\fInew_device\fR]\fR
1550 .ad
1551 .sp .6
1552 .RS 4n
1553 Replaces \fIold_device\fR with \fInew_device\fR. This is equivalent to attaching \fInew_device\fR, waiting for it to resilver, and then detaching \fIold_device\fR.
1554 .sp
1555 The size of \fInew_device\fR must be greater than or equal to the minimum size of all the devices in a mirror or \fBraidz\fR configuration.
1556 .sp
1557 \fInew_device\fR is required if the pool is not redundant. If \fInew_device\fR is not specified, it defaults to \fIold_device\fR. This form of replacement is useful after an existing disk has failed and has been physically replaced. In this case, the new disk may have the same \fB/dev\fR path as the old device, even though it is actually a different disk. \fBZFS\fR recognizes this.
1558 .sp
1559 .ne 2
1560 .mk
1561 .na
1562 \fB\fB-f\fR\fR
1563 .ad
1564 .RS 6n
1565 .rt  
1566 Forces use of \fInew_device\fR, even if its appears to be in use. Not all devices can be overridden in this manner.
1567 .RE
1568
1569 .RE
1570
1571 .sp
1572 .ne 2
1573 .mk
1574 .na
1575 \fB\fBzpool scrub\fR [\fB-s\fR] \fIpool\fR ...\fR
1576 .ad
1577 .sp .6
1578 .RS 4n
1579 Begins a scrub. The scrub examines all data in the specified pools to verify that it checksums correctly. For replicated (mirror or \fBraidz\fR) devices, \fBZFS\fR automatically repairs any damage discovered during the scrub. The "\fBzpool status\fR" command reports the progress of the scrub and summarizes the results of the scrub upon completion.
1580 .sp
1581 Scrubbing and resilvering are very similar operations. The difference is that resilvering only examines data that \fBZFS\fR knows to be out of date (for example, when attaching a new device to a mirror or replacing an existing device), whereas scrubbing examines all data to discover silent errors due to hardware faults or disk failure.
1582 .sp
1583 Because scrubbing and resilvering are \fBI/O\fR-intensive operations, \fBZFS\fR only allows one at a time. If a scrub is already in progress, the "\fBzpool scrub\fR" command terminates it and starts a new scrub. If a resilver is in progress, \fBZFS\fR does not allow a scrub to be started until the resilver completes.
1584 .sp
1585 .ne 2
1586 .mk
1587 .na
1588 \fB\fB-s\fR\fR
1589 .ad
1590 .RS 6n
1591 .rt  
1592 Stop scrubbing.
1593 .RE
1594
1595 .RE
1596
1597 .sp
1598 .ne 2
1599 .mk
1600 .na
1601 \fB\fBzpool set\fR \fIproperty\fR=\fIvalue\fR \fIpool\fR\fR
1602 .ad
1603 .sp .6
1604 .RS 4n
1605 Sets the given property on the specified pool. See the "Properties" section for more information on what properties can be set and acceptable values.
1606 .RE
1607
1608 .sp
1609 .ne 2
1610 .mk
1611 .na
1612 \fBzpool split\fR [\fB-n\fR] [\fB-R\fR \fIaltroot\fR] [\fB-o\fR \fIproperty=value\fR] \fIpool\fR \fInewpool\fR
1613 .ad
1614 .sp .6
1615 .RS 4n
1616 Split devices off \fIpool\fR creating \fInewpool\fR.  All \fBvdev\fRs in \fIpool\fR must be mirrors.  At the time of the split, \fInewpool\fR will be a replica of \fIpool\fR.
1617
1618 .sp
1619 .ne 2
1620 .mk
1621 .na
1622 \fB\fB-n\fR \fR
1623 .ad
1624 .sp .6
1625 .RS 4n
1626 Do dry run, do not actually perform the split. Print out the expected configuration of \fInewpool\fR.
1627 .RE
1628
1629 .sp
1630 .ne 2
1631 .mk
1632 .na
1633 \fB\fB-R\fR \fIaltroot\fR \fR
1634 .ad
1635 .sp .6
1636 .RS 4n
1637 Set \fIaltroot\fR for \fInewpool\fR and automaticaly import it.  This can be useful to avoid mountpoint collisions if \fInewpool\fR is imported on the same filesystem as \fIpool\fR.
1638 .RE
1639
1640 .sp
1641 .ne 2
1642 .mk
1643 .na
1644 \fB\fB-o\fR \fIproperty=value\fR \fR
1645 .ad
1646 .sp .6
1647 .RS 4n
1648 Sets the specified property for \fInewpool\fR. See the “Properties” section for more information on the available pool properties.
1649 .RE
1650
1651 .RE
1652
1653 .sp
1654 .ne 2
1655 .mk
1656 .na
1657 \fB\fBzpool status\fR [\fB-xv\fR] [\fIpool\fR] ...\fR
1658 .ad
1659 .sp .6
1660 .RS 4n
1661 Displays the detailed health status for the given pools. If no \fIpool\fR is specified, then the status of each pool in the system is displayed. For more information on pool and device health, see the "Device Failure and Recovery" section.
1662 .sp
1663 If a scrub or resilver is in progress, this command reports the percentage done and the estimated time to completion. Both of these are only approximate, because the amount of data in the pool and the other workloads on the system can change.
1664 .sp
1665 .ne 2
1666 .mk
1667 .na
1668 \fB\fB-x\fR\fR
1669 .ad
1670 .RS 6n
1671 .rt  
1672 Only display status for pools that are exhibiting errors or are otherwise unavailable. Warnings about pools not using the latest on-disk format will not be included.
1673 .RE
1674
1675 .sp
1676 .ne 2
1677 .mk
1678 .na
1679 \fB\fB-v\fR\fR
1680 .ad
1681 .RS 6n
1682 .rt  
1683 Displays verbose data error information, printing out a complete list of all data errors since the last complete pool scrub.
1684 .RE
1685
1686 .RE
1687
1688 .sp
1689 .ne 2
1690 .mk
1691 .na
1692 \fB\fBzpool upgrade\fR\fR
1693 .ad
1694 .sp .6
1695 .RS 4n
1696 Displays pools which do not have all supported features enabled and pools formatted using a legacy ZFS version number. These pools can continue to be used, but some features may not be available. Use "\fBzpool upgrade -a\fR" to enable all features on all pools.
1697 .RE
1698
1699 .sp
1700 .ne 2
1701 .mk
1702 .na
1703 \fB\fBzpool upgrade\fR \fB-v\fR\fR
1704 .ad
1705 .sp .6
1706 .RS 4n
1707 Displays legacy \fBZFS\fR versions supported by the current software. See \fBzfs-features\fR(5) for a description of feature flags features supported by the current software.
1708 .RE
1709
1710 .sp
1711 .ne 2
1712 .mk
1713 .na
1714 \fB\fBzpool upgrade\fR [\fB-V\fR \fIversion\fR] \fB-a\fR | \fIpool\fR ...\fR
1715 .ad
1716 .sp .6
1717 .RS 4n
1718 Enables all supported features on the given pool. Once this is done, the pool will no longer be accessible on systems that do not support feature flags. See \fBzfs-features\fR(5) for details on compatability with systems that support feature flags, but do not support all features enabled on the pool.
1719 .sp
1720 .ne 2
1721 .mk
1722 .na
1723 \fB\fB-a\fR\fR
1724 .ad
1725 .RS 14n
1726 .rt
1727 Enables all supported features on all pools.
1728 .RE
1729
1730 .sp
1731 .ne 2
1732 .mk
1733 .na
1734 \fB\fB-V\fR \fIversion\fR\fR
1735 .ad
1736 .RS 14n
1737 .rt
1738 Upgrade to the specified legacy version. If the \fB-V\fR flag is specified, no features will be enabled on the pool. This option can only be used to increase the version number up to the last supported legacy version number.
1739 .RE
1740
1741 .RE
1742
1743 .SH EXAMPLES
1744 .LP
1745 \fBExample 1 \fRCreating a RAID-Z Storage Pool
1746 .sp
1747 .LP
1748 The following command creates a pool with a single \fBraidz\fR root \fIvdev\fR that consists of six disks.
1749
1750 .sp
1751 .in +2
1752 .nf
1753 # \fBzpool create tank raidz sda sdb sdc sdd sde sdf\fR
1754 .fi
1755 .in -2
1756 .sp
1757
1758 .LP
1759 \fBExample 2 \fRCreating a Mirrored Storage Pool
1760 .sp
1761 .LP
1762 The following command creates a pool with two mirrors, where each mirror contains two disks.
1763
1764 .sp
1765 .in +2
1766 .nf
1767 # \fBzpool create tank mirror sda sdb mirror sdc sdd\fR
1768 .fi
1769 .in -2
1770 .sp
1771
1772 .LP
1773 \fBExample 3 \fRCreating a ZFS Storage Pool by Using Partitions
1774 .sp
1775 .LP
1776 The following command creates an unmirrored pool using two disk partitions.
1777
1778 .sp
1779 .in +2
1780 .nf
1781 # \fBzpool create tank sda1 sdb2\fR
1782 .fi
1783 .in -2
1784 .sp
1785
1786 .LP
1787 \fBExample 4 \fRCreating a ZFS Storage Pool by Using Files
1788 .sp
1789 .LP
1790 The following command creates an unmirrored pool using files. While not recommended, a pool based on files can be useful for experimental purposes.
1791
1792 .sp
1793 .in +2
1794 .nf
1795 # \fBzpool create tank /path/to/file/a /path/to/file/b\fR
1796 .fi
1797 .in -2
1798 .sp
1799
1800 .LP
1801 \fBExample 5 \fRAdding a Mirror to a ZFS Storage Pool
1802 .sp
1803 .LP
1804 The following command adds two mirrored disks to the pool \fItank\fR, assuming the pool is already made up of two-way mirrors. The additional space is immediately available to any datasets within the pool.
1805
1806 .sp
1807 .in +2
1808 .nf
1809 # \fBzpool add tank mirror sda sdb\fR
1810 .fi
1811 .in -2
1812 .sp
1813
1814 .LP
1815 \fBExample 6 \fRListing Available ZFS Storage Pools
1816 .sp
1817 .LP
1818 The following command lists all available pools on the system. In this case, the pool \fIzion\fR is faulted due to a missing device.
1819
1820 .sp
1821 .LP
1822 The results from this command are similar to the following:
1823
1824 .sp
1825 .in +2
1826 .nf
1827 # \fBzpool list\fR
1828      NAME    SIZE  ALLOC   FREE  EXPANDSZ    CAP  DEDUP  HEALTH  ALTROOT
1829      rpool  19.9G  8.43G  11.4G         -    42%  1.00x  ONLINE  -
1830      tank   61.5G  20.0G  41.5G         -    32%  1.00x  ONLINE  -
1831      zion       -      -      -         -      -      -  FAULTED -
1832 .fi
1833 .in -2
1834 .sp
1835
1836 .LP
1837 \fBExample 7 \fRDestroying a ZFS Storage Pool
1838 .sp
1839 .LP
1840 The following command destroys the pool \fItank\fR and any datasets contained within.
1841
1842 .sp
1843 .in +2
1844 .nf
1845 # \fBzpool destroy -f tank\fR
1846 .fi
1847 .in -2
1848 .sp
1849
1850 .LP
1851 \fBExample 8 \fRExporting a ZFS Storage Pool
1852 .sp
1853 .LP
1854 The following command exports the devices in pool \fItank\fR so that they can be relocated or later imported.
1855
1856 .sp
1857 .in +2
1858 .nf
1859 # \fBzpool export tank\fR
1860 .fi
1861 .in -2
1862 .sp
1863
1864 .LP
1865 \fBExample 9 \fRImporting a ZFS Storage Pool
1866 .sp
1867 .LP
1868 The following command displays available pools, and then imports the pool \fItank\fR for use on the system.
1869
1870 .sp
1871 .LP
1872 The results from this command are similar to the following:
1873
1874 .sp
1875 .in +2
1876 .nf
1877 # \fBzpool import\fR
1878   pool: tank
1879     id: 15451357997522795478
1880  state: ONLINE
1881 action: The pool can be imported using its name or numeric identifier.
1882 config:
1883
1884         tank        ONLINE
1885           mirror    ONLINE
1886             sda     ONLINE
1887             sdb     ONLINE
1888
1889 # \fBzpool import tank\fR
1890 .fi
1891 .in -2
1892 .sp
1893
1894 .LP
1895 \fBExample 10 \fRUpgrading All ZFS Storage Pools to the Current Version
1896 .sp
1897 .LP
1898 The following command upgrades all ZFS Storage pools to the current version of the software.
1899
1900 .sp
1901 .in +2
1902 .nf
1903 # \fBzpool upgrade -a\fR
1904 This system is currently running ZFS pool version 28.
1905 .fi
1906 .in -2
1907 .sp
1908
1909 .LP
1910 \fBExample 11 \fRManaging Hot Spares
1911 .sp
1912 .LP
1913 The following command creates a new pool with an available hot spare:
1914
1915 .sp
1916 .in +2
1917 .nf
1918 # \fBzpool create tank mirror sda sdb spare sdc\fR
1919 .fi
1920 .in -2
1921 .sp
1922
1923 .sp
1924 .LP
1925 If one of the disks were to fail, the pool would be reduced to the degraded state. The failed device can be replaced using the following command:
1926
1927 .sp
1928 .in +2
1929 .nf
1930 # \fBzpool replace tank sda sdd\fR
1931 .fi
1932 .in -2
1933 .sp
1934
1935 .sp
1936 .LP
1937 Once the data has been resilvered, the spare is automatically removed and is made available for use should another device fails. The hot spare can be permanently removed from the pool using the following command:
1938
1939 .sp
1940 .in +2
1941 .nf
1942 # \fBzpool remove tank sdc\fR
1943 .fi
1944 .in -2
1945 .sp
1946
1947 .LP
1948 \fBExample 12 \fRCreating a ZFS Pool with Mirrored Separate Intent Logs
1949 .sp
1950 .LP
1951 The following command creates a ZFS storage pool consisting of two, two-way mirrors and mirrored log devices:
1952
1953 .sp
1954 .in +2
1955 .nf
1956 # \fBzpool create pool mirror sda sdb mirror sdc sdd log mirror \e
1957    sde sdf\fR
1958 .fi
1959 .in -2
1960 .sp
1961
1962 .LP
1963 \fBExample 13 \fRAdding Cache Devices to a ZFS Pool
1964 .sp
1965 .LP
1966 The following command adds two disks for use as cache devices to a ZFS storage pool:
1967
1968 .sp
1969 .in +2
1970 .nf
1971 # \fBzpool add pool cache sdc sdd\fR
1972 .fi
1973 .in -2
1974 .sp
1975
1976 .sp
1977 .LP
1978 Once added, the cache devices gradually fill with content from main memory. Depending on the size of your cache devices, it could take over an hour for them to fill. Capacity and reads can be monitored using the \fBiostat\fR option as follows: 
1979
1980 .sp
1981 .in +2
1982 .nf
1983 # \fBzpool iostat -v pool 5\fR
1984 .fi
1985 .in -2
1986 .sp
1987
1988 .LP
1989 \fBExample 14 \fRRemoving a Mirrored Log Device
1990 .sp
1991 .LP
1992 The following command removes the mirrored log device \fBmirror-2\fR.
1993
1994 .sp
1995 .LP
1996 Given this configuration:
1997
1998 .sp
1999 .in +2
2000 .nf
2001    pool: tank
2002   state: ONLINE
2003   scrub: none requested
2004 config:
2005
2006          NAME        STATE     READ WRITE CKSUM
2007          tank        ONLINE       0     0     0
2008            mirror-0  ONLINE       0     0     0
2009              sda     ONLINE       0     0     0
2010              sdb     ONLINE       0     0     0
2011            mirror-1  ONLINE       0     0     0
2012              sdc     ONLINE       0     0     0
2013              sdd     ONLINE       0     0     0
2014          logs
2015            mirror-2  ONLINE       0     0     0
2016              sde     ONLINE       0     0     0
2017              sdf     ONLINE       0     0     0
2018 .fi
2019 .in -2
2020 .sp
2021
2022 .sp
2023 .LP
2024 The command to remove the mirrored log \fBmirror-2\fR is:
2025
2026 .sp
2027 .in +2
2028 .nf
2029 # \fBzpool remove tank mirror-2\fR
2030 .fi
2031 .in -2
2032 .sp
2033
2034 .LP
2035 \fBExample 15 \fRDisplaying expanded space on a device
2036 .sp
2037 .LP
2038 The following command dipslays the detailed information for the \fIdata\fR
2039 pool. This pool is comprised of a single \fIraidz\fR vdev where one of its
2040 devices increased its capacity by 1GB. In this example, the pool will not 
2041 be able to utilized this extra capacity until all the devices under the
2042 \fIraidz\fR vdev have been expanded.
2043
2044 .sp
2045 .in +2
2046 .nf
2047 # \fBzpool list -v data\fR
2048    NAME         SIZE  ALLOC   FREE  EXPANDSZ    CAP  DEDUP  HEALTH  ALTROOT
2049    data        17.9G   174K  17.9G         -     0%  1.00x  ONLINE  -
2050      raidz1    17.9G   174K  17.9G         -
2051        c4t2d0      -      -      -        1G
2052        c4t3d0      -      -      -         -
2053        c4t4d0      -      -      -         - 
2054 .fi
2055 .in -2
2056
2057 .SH EXIT STATUS
2058 .sp
2059 .LP
2060 The following exit values are returned:
2061 .sp
2062 .ne 2
2063 .mk
2064 .na
2065 \fB\fB0\fR\fR
2066 .ad
2067 .RS 5n
2068 .rt  
2069 Successful completion. 
2070 .RE
2071
2072 .sp
2073 .ne 2
2074 .mk
2075 .na
2076 \fB\fB1\fR\fR
2077 .ad
2078 .RS 5n
2079 .rt  
2080 An error occurred.
2081 .RE
2082
2083 .sp
2084 .ne 2
2085 .mk
2086 .na
2087 \fB\fB2\fR\fR
2088 .ad
2089 .RS 5n
2090 .rt  
2091 Invalid command line options were specified.
2092 .RE
2093
2094 .SH SEE ALSO
2095 .sp
2096 .LP
2097 \fBzfs\fR(8), \fBzpool-features\fR(5)